Article Index
Working Pressure
Hydronic and Industrial Applications
All Pages

Working pressure

The following tables illustrate the permissible working pressures of the aquatherm piping systems based on a 50 year life-cycle. The balance between working pressure and operating temperature varies based on the wall thickness of the pipe, as well as the presence of a faser-composite layer. All wall thicknesses are determined by SDR (standard dimension ratio) in which the wall thickness is a ratio of the total diameter. For example, the wall of an SDR 6 pipe is 1/6 the total diameter of the pipe.

Potable water installations

Temperature

aquatherm greenpipe
SDR 11

aquatherm greenpipe
SDR 7.4

aquatherm greenpipe
faser-composite pipe SDR 7.4

Permissible working pressure (psi)

70°F

185

295

355

105°F

135

210

255

120°F

110

175

215

140°F

95

145

175

180°F

40

100

100

SDR = Standard Dimension Ratio (diameter-/wall thickness ratio)
Working pressure is valid for all pipe sizes of the same SDR.